openconfig_transport_line_protection moduleΒΆ
Data Classes
Identity Classes
openconfig_transport_line_protection
Revision: 2018-11-21
This model describes configuration and operational state data for optical line protection elements, deployed as part of a transport line system. An Automatic Protection Switch (APS) is typically installed in the same device as the amplifiers and wave-router, however an APS can also be a standalone device. In both scenarios, it serves the same purpose of providing protection using two dark fiber pairs to ensure the amplifiers can still receive a signal if one of the two fiber pairs is broken. The APS port details and directionality are shown below. The three major attributes, together with their modifiers, define the behavior of the APS and can be prioritized in the descending order as shown in the following table